Search results for "Waste water treatment"
showing 8 items of 8 documents
Cathodic reduction of hexavalent chromium coupled with electricity generation achieved by reverse-electrodialysis processes using salinity gradients
2014
Abstract A new approach for the simultaneous generation of electric energy and the treatment of waters contaminated by recalcitrant pollutants using salinity gradients was proposed. Reverse electrodialysis allows for the generation of electric energy from salinity gradients. Indeed, the utilization of different salt concentrations gives a potential difference between the electrodes which allows the generation of electric energy by using suitable electrolytes and an external circuit. The simultaneous generation of electric energy and the treatment of waters contaminated by Cr(VI) was successfully achieved for the first time by reverse electrodialysis processes using salinity gradients and pr…
DSC: software tool for simulation-based design of control strategies applied to wastewater treatment plants.
2011
This paper presents a computer tool called DSC (Simulation based Controllers Design) that enables an easy design of control systems and strategies applied to wastewater treatment plants. Although the control systems are developed and evaluated by simulation, this tool aims to facilitate the direct implementation of the designed control system to the PC of the full-scale WWTP (wastewater treatment plants). The designed control system can be programmed in a dedicated control application and can be connected to either the simulation software or the SCADA of the plant. To this end, the developed DSC incorporates an OPC server (OLE for process control) which facilitates an open-standard communic…
Application of the Morris method for screening the influential parameters of fuzzy controllers applied to wastewater treatment plants
2011
In this paper,we evaluate the application of a sensitivity analysis to help fine-tuning a fuzzy controller for a biological nitrogen and phosphorus removal (BNPR) plant. TheMorris Screeningmethod is proposed and evaluated as a prior step to obtain the parameter significance ranking. First, an iterative procedure has been performed in order to find out the proper repetition number of the elementary effects (r) of the method. The optimal repetition number found in this study (r = 60) is in direct contrast to previous applications of the Morris method, which usually use low repetition number, e.g. r = 10 ~ 20. Working with a non-proper repetition number (r) could lead to Type I error (identify…
Micropollutants removal in an anaerobic membrane bioreactor and in an aerobic conventional treatment plant
2012
The paper expresses an attempt to tackle the problem due to the presence of micropollutants in wastewater which may be able to disrupt the endocrine system of some organisms. These kinds of compounds are ubiquitously present in municipal wastewater treatment plant (WWTP) effluents. The aim of this paper is to compare the fate of the alkylphenols-APs (4-(tert-octyl)) phenol, t-nonylphenol and 4-p-nonylphenol and the hormones (estrone, 17ß-estradiol and 17¿-ethinylestradiol) in a submerged anaerobic membrane bioreactor (SAMBR) pilot plant and in a conventional activated sludge wastewater treatment plant (CTP). The obtained results are also compared with the results obtained in a previous stud…
Modelling anaerobic biomass growth kinetics with a substrate threshold concentration.
2004
Abstract Many bacteria have been observed to stop growing below a certain substrate threshold concentration. In this study, a modification of the Monod kinetics expression has been proposed to take into account this substrate threshold concentration observed in bacterial growth. Besides the threshold concentration no additional parameters have been added to the kinetic expression and so, only the substrate threshold concentration and the half-saturation constant have to be estimated for model calibration purposes. Furthermore, for parameter estimation purposes, practical identifiability of this new function has been studied and the results have been satisfactory. The new model has been appl…
Occurrence of priority pollutants in WWTP effluents and Mediterranean coastal waters of Spain
2011
A comprehensive study aimed at evaluating the occurrence, significance of concentrations and spatial distribution of priority pollutants (PPs) along the Comunidad Valenciana coastal waters (Spain) was carried out in order to fulfil the European Water Framework Directive (WFD). Additionally, PP concentrations were also analysed in the effluent of 28 WWTPs distributed along the studied area. In coastal waters 36 organic pollutants of the 71 analysed, including 26 PPs were detected although many of them with low frequency of occurrence. Only 13 compounds, which belong to four different classes (VOCs, organochlorinated pesticides, phthalates and tributyltin compounds (TBT)) showed a frequency o…
Biochemical profiling of temperate zone freshwater green microalgae grown in filtered and unfiltered recirculating aquaculture systems effluent and m…
2020
Viljelemällä mikroleviä kalojen kiertovesiviljelyn jätevedessä siitä voidaan poistaa ravinteita ja tuottaa niistä biomassaa. Menetelmää voidaan käyttää korvaamaan perinteistä jäteveden käsittelyä ja kehittämään vesiviljelyn kannattavuutta. Tässä työssä verrattiin kolmen eri viherlevälajin (Haematococcus pluvialis, Monoraphidium griffithii and Selenastrum sp.) kasvua, ravinteiden poistoa, sekä rasvahappo- ja aminohappoprofiileja, kun leviä kasvatettiin suodatetussa tai suodattamattomassa kiertovedessä tai levien elatusaineessa. Monoraphidium ja Selenastrum -lajien kasvunopeudet olivat pienemmät kiertovedessä (0.64 vrk-1 ja 0.50 vrk-1) kuin levien elatusaineessa (0.72 ja 0.59 vrk-1), mutta Ha…
Effect of temperature on anaerobic treatment of black water in UASB-septic tank systems
2007
The effect of northern European seasonal temperature changes and low temperature on the performance of upflow anaerobic sludge blanket (UASB)-septic tanks treating black water was studied. Three UASB-septic tanks were monitored with different operational parameters and at different temperatures. The results indicated the feasibility of the UASB-septic tank for (pre)treatment of black water at low temperatures with respect to removal of suspended solids and dissolved organic material. Inoculum sludge had little effect on COD(ss) removal, though in the start-up phase some poorly adapted inoculum disintegrated and washed out, thus requiring consideration when designing the process. Removal of …